Search Results

You are looking at 1-4 of 4

Severe Intraoperative Bronchospasm Treated with a Vibrating-Mesh Nebulizer
Leonard R. GoldenMD,
Helen Ann DeSimoneDDS,
Farhad YeroshalmiDMD,
Mindaugas PraneviciusMD, and
Mana SaraghiDMD
Article Category: Other
Volume/Issue: Volume 59: Issue 3
Online Publication Date: Jan 01, 2012
DOI: 10.2344/12-00003.1
Page Range: 123 – 126

incidence of asthma is higher in urban areas, in children of low socioeconomic status, and in those with a history of atopy. 3 , 4 The area in which our institution is located (Bronx, New York) has the highest incidence of asthma in New York State. 3 , 4 The current report presents a case of bronchospasm in a 3-year-old child that was refractory to all usual treatments. A therapy not previously reported as being used in the operating room, a vibrating-mesh membrane nebulizer (Aeroneb Professional Nebulizer [APN] System, AG-AP6000-US, Aerogen Ltd, Ireland), was used to

Download PDF
; Assembly of conventional anesthesia circuit with APN and size-specific connectors. A indicates the universal adapter (Intersurgical Incorporated, #1969, Liverpool, NY) with a 22-mm outer diameter (OD) and a 15-mm inner diameter (ID); B, the APN chamber; C, the straight connector (Intersurgical Incorporated, #1962, Liverpool, NY) with a 15-mm OD and 22-mm ID; and D, the APN control module, which connects to the APN chamber via a cable.
Leonard R. Golden,
Helen Ann DeSimone,
Farhad Yeroshalmi,
Mindaugas Pranevicius, and
Mana Saraghi

Assembly of conventional anesthesia circuit with APN and size-specific connectors. A indicates the universal adapter (Intersurgical Incorporated, #1969, Liverpool, NY) with a 22-mm outer diameter (OD) and a 15-mm inner diameter (ID); B, the APN chamber; C, the straight connector (Intersurgical Incorporated, #1962, Liverpool, NY) with a 15-mm OD and 22-mm ID; and D, the APN control module, which connects to the APN chamber via a cable.


Article Category: Other
Volume/Issue: Volume 59: Issue 4
Online Publication Date: Dec 01, 2012
Page Range: 172 – 172

Sympathomimetics, 159 Techniques, 127 TIVA, 107 Vibrating-mesh, 123 Volatile anesthetics, 154 Warming, 127

Article Category: Other
Volume/Issue: Volume 59: Issue 4
Online Publication Date: Dec 01, 2012
Page Range: 171 – 171

Tzermpos FH, 22 Crawford B, see Thikkurissy S, 143 Davidian E, see Patel AB, 82 DeSimone HA, see Golden LR, 123 Dhariwal DK, see Chegini S, 69 Epstein R, see Rashewsky S, 147 Farago PV, see Pochapski MT, 57 Ferguson F, see Rashewsky S, 147 Fonner AM, see Reed KL, 127 Fukayama H, see Wakita R, 62 Furuya H, see Yamamoto I, 87 Ganzberg S, see Kramer KJ, 107 Golden LR, Severe Intraoperative Bronchospasm Treated with a Vibrating-Mesh Nebulizer (case report